ENIT

F.A.Q.

How can I drive a SCR LNB or multiswitch ?

WARNINGS:

  • Switch on the instrument and set the SATELLITE operating mode;
  • Select the desired satellite and transponder;
  • Connect the instrument to a SCR signal source (LNB or multiswitch).


SCR PROCEDURE FOR THE FOLLOWING MODELS:

EASY METER, EASY METER T2, EASY METER Plus
and EASY METER Touch.

NOTE: The following procedure is used in the models that have mecchanical and TOUCH commands.

1) Press the “VOLUME” key;
2) Select the “CONFIGURATIONE MENU” and press ENTER;
3) Select "SAT SCR/dCSS" and press ENTER;
4) Select "LNB TYPE" and the model of your installed LNB;
5) Select "SCR USER" and select the number of user under test: for example, "USER N.1";
6) Press directly the “SAT” key to start the measurements, or the “SPECT" key to display the spectrum.

NOTE: On the bottom left part of the display alternatively appears the battery symbol and the selected SCR user number. To change the user number, repeat the above procedure, when on step 5 select the wanted "USER N.".

SCR PROCEDURE to "SCR TEST":
If you want to make, in SPECTRUM mode, a check of the output frequencies of the SCR LNB/multiswitch, after step 5 select and press "TEST".